Y8610U4001

Honeywell Y8610U4001 Intermittent Pilot Retrofit Kit

16 items left
The Y8610U is a complete kit for converting conventional standing pilot systems to intermittent pilot systems. It is used on gas-fired atmospheric furnaces, boilers, and heating appliances. Not for use on direct vent, induced draft, or power burner equipment. Meets ANSI Z21.71 standard for automatic intermittent pilot ignition systems on central furnaces and boilers. Features Use with natural or LP gas Includes gas valve, ignition module, pilot burner hardware, ignition cable, and wiring harness Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trail/delay sequence is repeated until the appliance lights or call for heat is removed.